Summary of Lighting Specifications for Non-televised Events
                       The following table is a summary of the criteria to be considered for non-televised events (example
                       given of a football stadium). It sets out the recommendations for horizontal  illuminance, uniformity
                       and the properties of lamps for each level of activity.



                         Activity Level     Horizontal Illuminance  Uniformity  Lamp Colour Temperature  Colour Rendering Index
                                                                              K (Kelvin)


                         Class                 Eh ave (lux)      U2              Tk                   Ra

                         Class III
                         National Games           750            0.7           >4,000                ≥65

                         Class II                 500            0.6            >4,000               ≥65
                         Leagues and Clubs

                         Class II                 200            0.5            >4,000               ≥65
                         Training and Recreation










                                     Diagram 9h:
                              Installation Planning
                                  (Non-televised)

















                                                                                                     Class |||
                                                                                               National Game