LOGISTICS AND WAREHOUSING
                LOGISTICS AND WAREHOUSING


                    RACK STORAGE


















































                Most businesses operate 24 hours a day. Hence, well-designed and energy-e cient lighting
                plays an important role in ensuring uniform illumination so that operations take place

                safely and smoothly.

                Rack storage areas are large open spaces with high ceilings. Goods are stacked vertically
                on the racks which are adjacent to one another with typical aisle distance of 2.5 metres.
                That is why special care is taken to ensure vertical illumination depending on the height
                and width of the gangways.
                Recommended Standards
                • Lux Levels: Horizontal - 200lux; Vertical - >100lux
                • Mounting Height: 7-8m

                • Aisle Width: 2.5m

                         Right optics          Good vertical            Low glare
                         to maximise           illumination for         for visual
                         lighting              uniform light            comfort
                         e ciency              distribution