FEATURES:


          u  CRCA steel sheet housing comprising of LEDs.
          u  Opal di user fixed in separate CRCA sheet frame.

          u  Opal di user frame is held in with screws and nylon strings
              and it can be suspended for easy maintenance.

          u  Finish: Housing is white powder coated.


                                                                                     Overall Tolerance ±3mm






































          TECHNICAL SPECIFICATION:


             GENERAL INFORMATION                                     OPERATING AND ELECTRICAL
             Product Category              LED Commercial Lighting   Input Voltage              140 to 270V AC
             System Wattage**              36W                       Input Frequency            50/60 Hz
             Luminous Flux**               3600 lm                   System Current in Amp.     0.15A
             Luminaire E cacy*             100 lm/W                  @240V AC
             Correlated Colour Temperature  5700K                    Power Factor               ≥ 0.95
             Colour Rendering Index        ≥80                       THD                        <10%
             Maintenance Lumen Output      50,000 hrs.               Built-in Surge Protection   3 kV
             Operating Temperature Range   -5°C to +50°C
             PRODUCT DATA AND ORDERING DATA                          APPROVAL
             Product Cat. Ref.             BZSSQL 36L LED WH GX      Ingress Protection         IP20
             Product Code                  113924
             Case Lot                      02 Nos.
             Net Weight                    2.8 kg Approx



           *As per the IS 16107 part 2- sec1 clause no. 8.3, measured luminaire e cacy shall not be less than 90% of rated value.
           **As per the IS 16107 part 2- sec1 and 16103 part 2, clause no. 7 and 8.1 respectively, measured luminaire wattage shall not vary
           by more than +10% of rated value and luminaire lumen shall not vary by less than -10% of rated value.